Baseline MOCON, Inc. markets a full line of gas detection equipment including the award winning piD-TECH® Plug-In Photoionization Sensor, Model 9000 and Model 8800 Total Hydrocarbon/VOC Analyzers, and Model 8900 automated online Gas Chromatographs 

  

 Baseline Series 8900 Gas Chromatograph

Baseline Series 8900 Gas Chromatograph                          Download printable brochure.

The Baseline® Series 8900 is a multi-purpose gas chromatograph designed to continuously monitor single or multiple gas components in a wide range of applications.

The analyzer is microprocessor based and contains powerful embedded firmware. This makes it an online instrument with GC technology that is virtually transparent to the end user. There are a variety of state of the art detector, calibration and gas train options offering the flexibility and precision necessary to analyze from sub-parts per billion (sub-ppb) to percent levels.

The 8900's automatic calibration is ideal for unattended operation. It can be set up on a bench-top or rack-mounted, and its compact size makes it transportable. There are a variety of industry standard outputs, such as network (LAN), RS232, multiple 4-20 mA or 0-20 mA, and multiple relays for concentration alarms, diagnostics or user specified timed events.

Gas chromatography applications are configured at the factory before delivery by running the SkyChrom™ software from Baseline®. The computer can be disconnected and the analyzer will operate independently. When connected to SkyChrom™, data can be collected in a universal text format with a user definable data export utility for custom reports. Chromatograms can be stored continuously or based on events such as alarms. Detector options include Photoionization Detector (PID), Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD).

 

Applications

  • Well logging-fast C1-C5
  • Area monitoring of toxic gases for industrial hygiene and safety - Ethylene Oxide, Acrylonitrile, Butadiene, Styrene, Epichlorohydrin and many others
  • Fenceline (perimeter) monitoring around industrial and remediation sites - BTEX and other VOC's
  • Scrubber efficiency - hydrocarbons and VOC's
  • Carbon bed breakthrough detection -solvents and organic compounds
  • Quality Assurance Monitoring, contaminant analysis or blending of industrial gases
  • Methane/Non-methane analysis
  • A list of over 200 detectable gases is available upon request
 

Features

  • Accurate & specific to a wide variety and range of gases
  • Continuous unattended operation, operates with or without a computer
  • Automatic calibration and baseline correction for long-term stability
  • Outputs include digital, user definable analog and user definable logic
  • PC based SkyChrom™ software stores multiple analytical methods and chromatograms
  • Multipoint sampling options
  • Onboard short-term data storage. 
 

 Specifications

Sampling

Internal 4, 8, 16 point sampling options (not available on an FID)
Single point analyzer for pre-filtered (≤ 0.1 microns), non-condensing samples

Valves

Standard: (1) 10-Port valve (additional valves optional)

Calibration

Automatic or Manual using a dedicated standard

Detector

Single or Dual detector

Oven Temperature

Ambient to 302ºF (150ºC) ± 0.2ºF (0.1ºC)

Output

Analog: Standard: (1) 0-20 mA or 4-20 mA loop power supplied, isolated.
Digital: Standard: RS-232 output, LAN (Local Area Network)

Relays

Standard: (5) programmable (latched/not, NE/NNE, NO/NC) as contact closure (1A @ 30Vdc).

Physical Dimensions

17.41" (44.2cm) W x 9.36" (23.8cm) H x 14.83" (37.7cm) D

Nominal Weight

30 lb (13.64 kg)

Configuration

Bench-top or rack-mount 19" (48.3cm) panel

Display

Digital vacuum fluorescent, 20 characters x 2 lines

Power

90 - 260 VAC, @ 50-60 Hz (as specified)

Operating Conditions

Temperature: 32-104 ºF (0-40 ºC)
Humidity: 0-95%, non-condensing

Gas Connections

1/4" (6.35mm) or 1/8" (3.175mm) O.D. tube fitting connectors or consult Baseline®

Enclosures

General purpose, wallmount, X-purged or Z-purged

Column

Packed or capillary (application specific)

   Options & Accessories

Samplers

Built-in or external sample pump
Injection port (on sample loop)
8950 Multipoint Sampler (4/8/16 pt) w/ up to 16 analog outputs & 32 relays

Detectors

Photoionization (PID) 10.6 eV or 11.7 eV
High-sensitivity (PID) <50ppt Benzene
Flame Ionization (FID)
Thermal Conductivity (TCD)
Consult Baseline® for other options.

Outputs

Analog output board - up to 20 additional programmable 4-20 mA outputs
Voltage outputs - 0-1 V, 0-5 V or 0-10 V (others on request)
Relay board - up to 32 additional programmable relays

Inputs

Optional digital input board for 3 contact closure inputs. Supports start analysis, start calibration, and analyze calibration gas sample.

Software

SkyChrom™ external integration, GC setup and data acquisition software for PC

Gas Generators

Zero air or Hydrogen

Calibration Methods

Gas cylinder, 8990 Permeation Calibrator, response factors

Home Page - Baseline Main Page

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com
Privacy PolicyTrade Mark StatementContact UsWebmail Login