 Draeger Polytron IR

The Dräger Polytron IR is an explosion proof infrared gas detector for continuous monitoring of combustible gases and vapors. With its stainless steel body and drift free optics this gas detector is built for harsh offshore environments.

Two models working with different wavelengths cover a broad range of detectable substances.

Technical Innovation - The model type 340 extends the area of applications for the Dräger Polytron IR product line. The different  wavelength of the Dräger Polytron IR type 340 offers detection of alkanes at an even higher sensitivity. The possible monitoring of cyclohexane presents one of various options for gas detection resulting from this innovation.

With both transmitter models Dräger Polytron IR type 340 and type 334, Dräger defines the status quo of measurement technology for continuous monitoring of ambient air regarding combustible gases and vapors. The Dräger Polytron IR works based on the physical principle of infrared absorption. The innovative double compensating and non-focussing optics effectively compensates temperature and ageing effects. With its many field proved components it sets the standard for safety relevant measurement requirements. It is approved by certification that the Dräger Polytron IR can be used for SIL 2 (safety integrity level) safety functions.

Configuration - Flexible is the configurable measuring range for the Dräger Polytron IR: Type 334 offers 0 to 20 %LEL and up to 100 %LEL, alternatively 0 to 100 %v/v for methane. For the type 340, the full scale is configurable from 5 to 100 %LEL. Configuration is menu guided and easy to perform, using a HART® handheld terminal.

Calibration - For the easy calibration of the Dräger Polytron IR, one gas needs to be selected from an internal list, and this gas can differ from the gas to be measured.

All data will be converted automatically to the substance to be monitored. So, the intricate use of factors for cross sensitivity calibration is no longer necessary. Thus for all Dräger Polytron IR transmitters there is only one calibration gas required, independent of the substance to be monitored.

Stand-by Mode (Preventive Maintenance Function) - Using a preventive maintenance function – stand-by mode – the Dräger Polytron IR does not immediately shutdown in case of dirty optics. Prior to providing a beam block fault signal, there will be a warning transmitted to the control system. The measurement continues in the background, and it will be switched back to normal operation when measuring gas concentrations of more than 15 %LEL. Alarming in a hazardous situation and with it the complete safety functionality will be maintained.

The Draeger Polytron IR offers:

  • Library including up to 38 substances
  • SIL 2 (safety integrity level) certified
  • Configurable measuring range
  • Precise measurement
  • No moving parts
  • Fast, accurate response
  • Dirty optics warning
  • Long maintenance intervals
  • Double compensating, non-focussing optics (4 beams)
  • Hermetically sealed SS 316 body
  • Ex-approvals for worldwide use
  • Dust-approval for zone 21, 22
  • Multidrop capability HART®, 4 to 20mA, RS 485
 

Technical Data

Type  

Explosion proof gas detector with infrared sensor technology 

Gases and ranges 

Combustible gases 0 to 5 … 100 %LEL (depending on substance )
 and vapors   0 to 350 … ppm (depending on substance)

 Longterm stability (drift) < 2 %LEL (measuring range 0 to 100 %LEL methane) / 2 years 
 Repeatability  < 2 %LEL (measuring range 0 to 100 %LEL methane)
 Response time t0…90 < 5 seconds
 Output signal analog   4 to 20 mA
 Output signals digital  HART®, RS 485
 Preventive maintenance function  2 mA in case of dirty optics
 Fault signal  < 1.2 mA
Signals for warning and maintenance configurable
 Power supply  15 to 30 VDC, < 5 W, 3-wire
 Ambient conditions  Temperature – 40 to +65 °C / – 40 to +150 °F (UL variants)
– 40 to +60 °C / – 40 to +140 °F (IECEx variants)
Pressure 700 to 1300 hPa / 23.6 to 32.5 inch Hg
Humidity 0 to 100 %RH, non-condensing
Enclosure     IP 66 and IP 67, NEMA 4 and 7
 Size  125 mm x 180 mm x 155 mm / 4.9'' x 7.1'' x 6.1'' (W x H x D)
 Weight  3.1 kg
 Approvals

 UL, CSA Class 1, Div 1, Groups B, C, D
ATEX II 2G EEx de [ia] IIC T5, II 2D IP 6X T100°C EN 50281-1-1
IECEx Ex de [ia] IIC T5, Ex tD A21 IP6X T100°C
Explosion protection and performance approval
EN 61779-1
EN 61779-4
EN 50271
CE-mark: electromagnetic compatibility (directive 2004/108/EC)
SIL 2 (safety integrity level) certified

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 