Horiba APHA-370 Ambient THC Monitor

Download printable brochure.

 Horiba APHA-370 THC

Overview

The APHA-370 continuously monitors atmospheric THC, NMHC, and CH4 concentrations using a cross-flow modulated selective combustion type method combined with a hydrogen ion detection method. The APHA-370 employs an independent, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy.
 

 Features

The APHA-370 uses a combination of the flame ionization detection method and selective-combustion.
This gives it the advantage of the single-detector method plus the ability to perform continuous measurements, free of zero-drift, for THC, NMHC, and CH4. The design gives great stability and high sensitivity (0-5 ppm F.S.)

The APHA-370 has a relative-sensitivity correction function for CH4 and NMHC.

All the necessary features are built right into a single rack-sized instrument, including a catalytic unit for selective combustion (i.e., an NMHC cutter); a cataytic unit for generating reference gas and auxiliary combustion air (standard); and a sampling pump. The only supplemental gas required is H2.

Manufactured by HORIBA

 

Specifications

Principle

Flame ionization detection (FID) with selective combustion

Application

THC, NMHC, and CH4 in ambient air

Range

Standard ranges: 0-5/10/20/50 ppmC; auto range ~ manual range selectable; can be operated by remote switching.
Optional (measurable) ranges: 4 ranges selectable from 0-100 ppmC, within 10 times range ratio;
auto range ~ manual range selectable; can be operated by remote switching.

Repeatability

±1.0% of F.S.

Linearity

±1.0% of F.S.

Sample gas flow rate

Approx. 0.9 L/min

Indication

Measured value, range, alarm, maintenance screen

Alarms

During AIC, zero calibration error, span calibration error, temperature error in zero gas purifier, ignition failure error, etc.

On-screen messages are available in four languages

English, German, French, and Japanese.

Input/output

• 0-1 V/0-10 V/4-20 mA, to be specified (2 systems: either (1) momentary value and integrated or (2) moving average value) 
• Contact input/output 
• RS-232C

Power

100/110/115/120/220/230/240 VAC, 50/60 Hz (to be specified)

Dimensions

430(W) x 550(D) x 221(H) mm

Mass

Approx. 33 kg,

Notes

ppmC is shown as symbol, not as unit.

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 