ETA Process Instrumentation - since 1971

ETA Process Instrumentation -- Since 1971

ETA Associates merged with Process Instrumentation Inc. as of 9/1/2011. Visit our sister companies: Safety Inc and iFacility Service.

     Home

  Manufacturers 

Industries & Instruments

Technical Resources

    Service   

     About      

 
Kanomax  Indoor Air Quality Monitor Model 2211                       Download printable brochure
Kanomax IAQ 2211

Multi-Parameter Indoor Air Quality Monitor - IAQ Investigation Environmental Health and General Safety Thermal Comfort Measurements

Features:

  • Simultaneously measure and log data with multiple parameters such as CO, CO2, Temperature, Relative Humidity, to monitor indoor air quality conditions
  • Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air
  • Built-in memory allows user to store multiple point measurements

Benefits:

  • Easy user calibration with built-in calibration function
  • Capable to continuously monitor parameters via PC
  • Large LCD shows multiple parameters at a glance
 

Specifications:

 CO  Range  0 – 500PPM
 Accuracy  +/-3% of reading or 3PPM whichever is greater
 CO2  Range     0 – 5000PPM

 Accuracy

 +/-3% of reading or +/-50PPM whichever is greater
 Temperature  Range  -4 – 140ºF (-20 – 60ºC)
 Accuracy  +/- 1ºF (+/-0.5ºC)
 Relative Humidity  Range  2 – 98%RH
 Accuracy  2 – 80%RH: +/-2%RH, 80 – 98%RH: +/-3%RH
 Functions  Normal Mode  Normal measuring: Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity, and Humidity Ratio
 Calculation Mode  Store the data, and calculate the maximum, minimum and average value
 % OA Mode  Measure ventilation ratio
 Data Output Mode  Perform re-calculation of stored data and output of data to PC and Printer.
 Calibration Mode  Perform the calibration of CO and CO2.
 Outputs  Digital  RS-232C (Baud rates:4800,9600,19200,38400bps)
 Analog (Option)  DC0~1V (Select 1 ch among CO, CO2, temperature, and relative humidity)
 Power Supply  AA Battery×6 (Alkaline or Ni-Cd), AC adapter:AC100~240V (50/60Hz)(Optional)
 Battery Life  Approximately 10 hours (at 77ºF (25ºC) with alkaline batteries, without RS232C)
 Operating Environment  Main Body  41-104ºF (5~40ºC)
 Probe  - 4 - 140ºF (-20~60ºC)
 Storage Environment  - 4-140ºF (-20~60ºC)
 Standard Kit  Mn Battery × 6, Calibration cap, Connection tube
 Optional Accessories  Analog Output, Serial Printer, Communication Cable (For Computer and Printer), AC Adapter

Back to Kanomax Main Page - Home

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com
Privacy PolicyTrade Mark StatementContact UsWebmail Login