Sample Conditioning
|
|
Filtration:
|
Heated unit with replaceable element
180 °C / 356 °F suitable for most applications
280 °C / 536°F for applications where ammonia is present in the flue gas
|
|
Filter Element:
|
1.0 µm ceramic
|
|
Sample Cooler:
|
2-stage cooler system (incorporating Peltier unit) with automatic condensate removal
|
Blow-back
|
|
Method:
|
Heated, filtered, compressed air
|
|
Triggers:
|
Internal timer; external trigger (via digital link); Manual (push button); +24 V external drive
|
|
Temperature:
|
150 °C / 300 °F
|
|
Timer Interval:
|
15 minutes to 24 hours user selectable
|
|
Duration:
|
3 secs
|
Control System
|
|
Communications:
|
Remote control via RS 485 digital link
|
|
Automatic Controls:
|
Filter temperature; Cooler temperature; Condensate removal; Blow-back timing; Blow-back air temperature
|
|
Manual Controls:
|
Blow-back trigger
|
|
Status LEDs:
|
Power; Blow-back; System OK; Communications
|
Status Outputs (via
digital link):
|
Filter temperature; Blow-back air temperature; Blow-back pressure; Cooler Temperature; Enclosure temperature; Condensate pumps active; Sample gas temperature (optional)
|
|
Alarms (indicated at analyzer):
|
Filter temperature (low/high)
Blow-back accumulator temperature (low/high)
Cooler temperature (low/high)
Blow-back accumulator low pressure
Moisture slip
Pump fault
|
|
Relay Outputs:
|
System OK; Blow-back in progress; Filter cold; Cooler fault
|
|
Additional Output:
|
Power for anti-freeze condensate sample line
|
Environmental
|
|
|
Enclosure:
|
Stainless steel sealed to the requirements of IP 65 / NEMA 4X
|
|
Operating Temperature:
|
-25 to + 55 °C / -13 to +131 °F (option to -40 °C / -40 °F)
|
|
Compliance
|
|
EMC:
|
Conforms to EN-61326 (Class A)
|
|
Electrical Safety:
|
Conforms to EN-61010-2
|
Power
|
|
Power Supply:
|
110 or 230 V a.c., ±10%, 50 or 60 Hz
|
|
Power Consumption:
|
900 W
|
Air Requirements
|
|
Air Requirements for cooling:
|
Dependent upon ambient temperature and process conditions
|
Dimensions
(H x W x D)
|
685 x 510 x 356 mm / 27 x 20 x 14 in
|
|
Weight:
|
56 kg / 124 lb
|
|
Mounting:
|
Single flange - 3" ANSI, 150 lb type
|
|
Flange Temperature:
|
up to 180 °C / 356 °F without adaptor
up to 500 °C / 932 °F with adaptor
|
Optional Flange
Adaptor:
|
2", 3", or 4" ANSI 150 lb; DN65 PN6
|
Probe Pipes and Materials
|
|
316 Stainless Steel :
|
up to 600 °C / 1112 °F
|
|
Hastelloy C-276:
|
up to 900 °C / 1652 °F
|
|
Hastelloy X:
|
up to 1200 °C / 2200 °F
|
|
Mullite:
|
up to 1700 °C / 3100 °F
|
|
Lengths*:
|
0.5 m / 1.6 ft; 1.0 m / 3.3 ft; 1.5 m / 5 ft; 2.0 m / 6.6 ft
|
|
Probe Pre-filter#:
|
2.0 µm Sintered stainless steel (Temp. <400 °C / 750 °F)
2.0 µm Hastelloy (Temp. up to 800 °C / 1470 °F)
|
* Mullite probes only available in 0.5 and 1.0m lengths
# Available with all probe types except mullite:
|
Options
|
|
Sample Gas Cooler Temp. sensor:
|
Type K thermocouple
|
|
Air blower for instrument cooling:
|
Low capacity or high capacity blower units
|