Specifications
|
|
Measuring
|
|
Technique:
|
Cross stack, double pass / path transmissometry
|
|
Operating Wavelength:
|
520 ± 20 mm
|
|
Light Source:
|
High Intensity LED
|
|
Range:
|
Opacity 0 - 10 % to 0 - 100%
Optical Density 0 - 0.1 to 0 - 3.0
Dust Density 0 - 10 to 0 - 4000 mg/m3
User Selectable
|
|
Accuracy:
|
±0.5% Opacity
|
|
Linearity
|
<2% of range
|
|
Resolution:
|
0.1% Opacity: 0.001 Optical Density; 0.1 mg/m3 Dust
|
|
Suitable for Stacks diameter:
|
2 ft. to 82 ft / 0.6 to 25 m
|
|
Installation Pathlength:
|
3 ft to 82 ft / 0.97 to 25 m
|
|
Calibration:
|
Automatic Zero and upscale calibration
Selectable period 1 to 24 hours in 1 hour steps
|
|
Response Time:
|
<10s
(<2s with no damping)
|
|
Calibration Error per ASTM D6216:
|
<1% Opacity
|
|
24 Hour Drift:
|
<0.3% Opacity
|
|
Long Term Drift:
|
<0.3% Opacity per month
|
|
Voltage Variation per ASTM D6216:
|
<0.2% Opacity (over 85 - 265 V a.c.)
|
|
Thermal Stability per ASTM D6216:
|
<0.3% Opacity
(over -4 to +131º F / -20 to +55º C) range)
|
|
Ambient Light Sensitivity per ASTM D6216:
|
<0.3% Opacity
|
|
Insensitivity to misalignment:
|
<0.2% Opacity for ±0.25º misalignment
|
|
Environmental
|
|
Operating Temperature:
|
-4 to +131º F / -20 to +55º C)
(-40º F / -40º C with optional heater)
|
|
Max. Flue Gas Temperature:
|
1112º F / 600º C
|
|
Max Flange Temperature:
|
392º F / 200º C
|
|
Outputs
|
|
Modbus Interface:
|
RS232 or RS485. Opacity, Dust, Optical Density, Status, Averaging and Range information available.
|
|
Analogue output:
|
Two isolated 4-20mA current outputs
Independently configurable as Opacity, Dust Optical Density, Calibration Drift or OPLR
|
|
Relay outputs:
|
System OK, Span calibration, zero calibration, Alarm 1, Alarm 2, Maintenance
|
Options
Air Blower Units
Automatic Fail-Safe Shutters
Weather Covers
Control Room Unit
Alignment Tool
Calibration Filters
|