Thermo Scientific

 


 

Thermo Process Monitoring and Industrial Instruments

Flow, Density and Level Measurement - Continuous, Point and Tilt Level Measurement

Continuous, point, sonic and tilt level measurement controllers. Increase process efficiency, run a safer system, produce higher quality products and improve your bottom line.

 

Thermo DensityPro Integrated Gamma Density system with HART protocol 

DensityPRO Integrated Gamma Density System with HART protocol                                    Download printable brochure

Thermo Scientific* DensityPRO Integrated gamma density system gauge offers users a wide range of features normally found in systems costing significantly more, all in a small, integrated package designed to minimize installation costs. Incorporates a detection and measurement design allowing for use of extremely small sources in the most challenging process conditions.
 
The DensityPRO system offers users a wide range of features normallyfound in systems costing significantly more--all in a small integratedpackage designed to minimize installation costs. The DensityPROincorporates a detection and measurement design allowing for use ofextremely small sources in the most challenging process conditionswhere pipe sizes may range from 1" (25.4 mm) to 42" (1066.8 mm).

  • Non-contacting design makes the DensityPRO ideal for abrasive, corrosive, high pressure and high temperature applications
  • Integrated transmitter/detector reduces installation and wiring costs
  • Sophisticated temperature stabilization technique provides unmatched performance in the most challenging applications
  • Easy-to-use English language user interface makes for simple set-up and calibration
  • Isolated loop-powered, isolated or non-isolated self-powered current output available
  • PVT (Polyvinyl Toluene) scintillation detector resistant to moisture and shock damage
  • Availablecommunication options include HART protocol, Thermo Scientific Model9734 handheld communicator and TN Comm PC user interface. The Model9734 eases installation time by allowing uploads/downloads of gaugeconfiguration to/from PC
  • Self-diagnostic and alarm history software reduce troubleshooting time

Certifications: CE marked; CSA-US ,ATEX approved

Recommended for:
  • Ideal for product process lines
  • Product interface detection
Specifications
Performance Specifications
Precision From ±0.001g/cc depending upon application
Repeatability ±0.001g/cc depending upon application
Stability Drift less than ±0.05% of radiation change over 6 months
Resolution Analog output 16-bit Internal instrumental IEEE754 floating point
Magnetic Field Effect No effect on output when tested to IEC 770 para. 6.2.11
Ambient Temperature Field ±0.09% of radiation change per °C; ±0.06% of radiation change per °C
Surface Radiation Dependent on the application, source selection and physical installation
Power Available options: 115/230VAC ±10%; 50 to 60Hz or 24VDC or 12VDC; Surge protected 9 to 35VDC
Power Supply Effect No effect on operation over specified power supply ranges
Gamma Ray Source
Type Cs-137 or Co-60, both stainless steel, doubly encapsulated
Size 10 to 10,000mCi Cs-137 or 1000 to 3000mCi Co-60
52XX Series Source Heads ANSI Accident Condition Fire Test 3
Functional Specifications
Detector/Electronics PVT plastic scintillator with wide dynamic range (PVT resists shock and moisture damage);

Stabilization via electronic control without heater stabilization for optimum performance
Operating Temperature Limits Transmitter/Detector: -40°C to +60°C (-40°F to +140°F) ambient
Storage Temperature Limits -0°C to +65°C (-22°F to +149°F)
Inputs Flowmeter: 4 to 20mA linear; Dry contact closure; Temperature compensation circuitry with 100ohm platinum RTD 2 or 3 wire
Current Outputs 4 to 20mA isolated, loop-powered into 700ohm, field scalable; 4 to 20mA isolated, self-powered into 700ohms, field scalable; 4 to 20mA non-isolated, self-powered into 700ohms, field scalable
Serial Outputs RS 423 or Bell 202 interface with HART* protocol; Digital signal superimposed on 4 to 20mA signal using HART protocol, available for control system interface; Digital signal available via intrinsically safe connection for HART Communicator
Contact Closure Inputs Two programmable dry contact inputs
Contact Closure Outputs Two 115VAC/28VDC SPDT @ 10A (230VAC SPDT @ 8A)
Source Decay Compensation Selectable Cs-137, Co-60 or Am-241
Linearization Logarithmic function and ratio linearization
Analog Output Adjustment Engineering units and range values user-selected; All analog trim and adjustments made through software commands
Adjustable Damping 1 to 1040 sec.
Adaptive Damping See Dynamic Process Tracking
Dynamic Process Tracking Selectable; Automatic 8 to 1 time constant reduction based on process rate of change
Transmitter System architecture: Multiprocessor-based electronics provide uninterrupted output during data entry and system interrogation;

Surface-mounted technology provides high degree of reliability; All user data doubly stored in non-volatile memory with no battery backup required; Programming options: Menu-driven offers direct keypad entry; HART Smart Model 375 handheld terminal: used to setup and calibrate gauge, and to enter data; Communicates with any DensityPRO via the current loop;

BEL202FSK standard; Thermo Scientific 9734 handheld terminal: used to setup and calibrate gauge, and to enter data; communicates with any DensityPRO via the RS485 connector; provides upload/download of gauge configuration to/from PC via RS232 interface; Comm PC Interface Software: interface with up to 32 DensityPRO units over RS485 loop (RS485 to RS232 converter provided)
Physical Specifications
Electrical Connections Two 3/4 in. NPT fittings; HART Communicator interface connects directly into 4 to 20mA loop
Interface Cable Shielded 14 to 22 gauge Belden 9318
Transmitter Display Thermo Scientific 9734 handheld terminal
Gauge Mounting Hardware Gamma ray source: integral bolt-on bracket; Compatible with chain or saddle mount; Transmitter/Detector: single or dual chain universal mount 2.5 in. (63.5mm) to 36 in. (914.4 mm); Pipe saddle mount 2 in. (50.8mm) to 42 in. (1066.8mm); Tabs for mounting on insulated pipes
Housing Detector: Carbon steel polyurethane painted or optional stainless steel 316; Source: carbon steel or optional stainless steel 316, lead filled, polyurethane painted; two position shutter, locks in closed position
Detector PVT plastic scintillator with wide dynamic range; Resists shock and moisture damage
Weight, Detector/Electronics 10 lb. (4.5kg)
 

 

4 G Technologies • Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes OptechPercival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 

ETA Process Instrumentation, 119 Foster Street, Bldg. 6, Peabody, MA 01960 • (978) 532-1330 or sales(a)etapii.com