Flow, Density and Level Measurement - Continuous, Point and Tilt Level Measurement

Continuous, point, sonic and tilt level measurement controllers. Increase process efficiency, run a safer system, produce higher quality products and improve your bottom line.

Thermo Texas Nuclear Kay Ray Sensall Sapphire Single Point 

Sapphire Single-Point Level System                                       Download printable brochure

Thermo Scientific Sapphire single-point level system performs well in aerated, attenuative, viscous, corrosive, and even more severe applications.
It combines a unique measurement technique with superior self-testing capabilities to ensure reliability and increase uptime. Based on time-gate technology, the system uses an advanced form of ultrasonic measurement to offer increased sensitivity. To guard against false alarms, the variable system qualification time accurately determines the presence of liquid in the measurement gap.Details:
 
Details:
 
  • Gap or slot sensor configurations
  • Continuous self-test for unmatched reliability
  • Manual loop test
  • Dual-compartment housing
  • Lowest total installed cost
  • Broad range of sensor materials
  • 3A sanitary finish and fittings

Compliance: CSA-US

Certifications: CSA-US

Single-Point (when installed per drawing 952-000099): Class I, Groups B, C & D; Class II; Class III; Class I, Div 2,

Groups A, B, C and D; Enclosure Type 4

Single-Point and Remote Relay Level Switches (when installed per drawing 952-000066):

Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III; Enclosure Type 4

Dual-Point/Remote Dual-Point (when installed per drawing 952-000118): Class I, Groups B, C and D; Class II,

Groups E, F and G; Class III; Class I, Div 2, Groups A, B, C and D; Enclosure Type 4

  Specifications
  Electronics—Relay Operation (integral and remote)
Supply Voltage Model F: 15-35VDC

Model G: 115VAC, ±10%, 50/60Hz

Model S: 230VAC, ±10%, 50/60Hz
Power Consumption 4w max. (2W typical)
Outputs 2 relay outputs; Process relay is field-selectable for Hi/Lo operation; Auxiliary relay is field-selectable for Fault/Mimic operation and NC/NO operation
Process (SPDT1) Relay Maximum contact rating: 5A at 115/250VAC or 5A at 30VDC

Minimum contact rating: 100mA at 5VDC or 15mA at 24VDC
Auxiliary (SPST1) Relay Maximum contact rating: 5A at 115/250VAC or 5A at 30VDC

Minimum contact rating: 100mA at 5VDC or 15mA at 24VDC
  Electronics—Two-Wire Operation (integral and remote)
Supply Voltage Model J: 12-55VDC
Power Consumption 1.1w maximum
Current Loop Loads Rload, max = (Vsupply-12) x 50 ohms
Analog Output (±1mA) 19mA/5mA self-test fault (field-selectable)

8mA dry/16mA wet (field-selectable)

16mA dry/8mA wet (field-selectable)
  Operating Specifications—Relay and Two-Wire
Self-Test Continuous for electronics and sensor, including crystal bond to sensor body
Manual Loop Test All output conditions momentarily change to the opposite state (except when in a fault condition) when supplied magnet

is placed over the housing cover at the location marked “Loop Test”
Sensor Qualification Time 0.3 or 12 seconds, field-selectable
Repeatability ±0.1 in.
Enclosure Single-Point: dual-compartment NEMA 4X (ANSI 250 Type 4X) enclosure housing; Materials include low copper aluminum, polyurethane paint, Buna-N O-rings

Dual-Point: single-compartment NEMA 4 (ANSI 250 Type 4) enclosure housing; Materials include low copper aluminum, polyurethane paint, Buna-N O-rings
Connection Single 0.5-in NPT conduit connections; Wire range is 22 AWG to 12 AWG
Temperature Range Electronics: -40°C to +70°C (-40°F to +158°F)

Sensors: -40°C to +160°C (-40°F to +320°F); -190°C to +100°C (-310°F to +212°F)
Humidity 10% to 95% RH, non-condensing
Operating Pressure -10 to +1000 psig (-69 to +6895KPa)
Proof Pressure 1500 psig (10342KPa)
  Physical Specifications
Materials Gap: 316 SS, Hastelloy C, Monel, Hastelloy B, Carpenter 20, titanium; Slot: 316 SS, Hastelloy C
Weight (incl 3/4 in. NPT) Single-Point model: 4 lb. (1.8kg); Dual-Point model: 6 lb. (2.7kg)
1 Both SPDT and SPST relays have gold-plated contacts and de-energize on process alarm, self-test or power loss
 

Home - Thermo Thermo Brandt - Thermo Sarasota - Thermo Texas Nuclear Kay/Ray Sensall - Thermo Westronics 

Ametek Badger Meter Baseline Mocon Berkeley Nucleonics • BH Thermal Corp Brandt - Thermo Bud Industries Ceasefire Chandler Engineering - Ametek • Daniel Industries Dent Instruments Draeger Gas Detection Systems • Dycor - Ametek • FasTest • Fox Thermal Instruments Gasmet H2Scan Hawk Measurement Systems Horiba ION Science JMS Southeast • Kahn Instruments Kanomax Lakewood Instruments Land - Ametek • Magnatrol Valve Martel Electronics/Beta Calibrators • Measurement Technologies Odor Eyes • Percival ScientificPerma Pure LLCProcess Instruments - Ametek • Process Sensors • Racine/Preso Flow MeteringR. StahlRKI InstrumentsRosemount Tank GaugingSarasota - Thermo • SpectiteTexas Nuclear Kay/Ray Sensall - Thermo TestoThermo • Thermox - Ametek • Trace Analytical - Ametek United Electric ControlsWelkerWestern Research - Ametek • Westronics - Thermo • Wilkerson Instrument Co 