Sapphire Single-Point Level System Download printable brochure
Thermo Scientific Sapphire single-point level system performs well in aerated, attenuative, viscous, corrosive, and even more severe applications.
It combines a unique measurement technique with superior self-testing capabilities to ensure reliability and increase uptime. Based on time-gate technology, the system uses an advanced form of ultrasonic measurement to offer increased sensitivity. To guard against false alarms, the variable system qualification time accurately determines the presence of liquid in the measurement gap.Details:
Details:
- Gap or slot sensor configurations
- Continuous self-test for unmatched reliability
- Manual loop test
- Dual-compartment housing
- Lowest total installed cost
- Broad range of sensor materials
- 3A sanitary finish and fittings
Compliance: CSA-US
Certifications: CSA-US
Single-Point (when installed per drawing 952-000099): Class I, Groups B, C & D; Class II; Class III; Class I, Div 2,
Groups A, B, C and D; Enclosure Type 4
Single-Point and Remote Relay Level Switches (when installed per drawing 952-000066):
Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III; Enclosure Type 4
Dual-Point/Remote Dual-Point (when installed per drawing 952-000118): Class I, Groups B, C and D; Class II,
Groups E, F and G; Class III; Class I, Div 2, Groups A, B, C and D; Enclosure Type 4
|
|
Specifications
|
|
|
Electronics—Relay Operation (integral and remote)
|
|
Supply Voltage
|
Model F: 15-35VDC
Model G: 115VAC, ±10%, 50/60Hz
Model S: 230VAC, ±10%, 50/60Hz
|
|
Power Consumption
|
4w max. (2W typical)
|
|
Outputs
|
2 relay outputs; Process relay is field-selectable for Hi/Lo operation; Auxiliary relay is field-selectable for Fault/Mimic operation and NC/NO operation
|
|
Process (SPDT1) Relay
|
Maximum contact rating: 5A at 115/250VAC or 5A at 30VDC
Minimum contact rating: 100mA at 5VDC or 15mA at 24VDC
|
|
Auxiliary (SPST1) Relay
|
Maximum contact rating: 5A at 115/250VAC or 5A at 30VDC
Minimum contact rating: 100mA at 5VDC or 15mA at 24VDC
|
|
|
Electronics—Two-Wire Operation (integral and remote)
|
|
Supply Voltage
|
Model J: 12-55VDC
|
|
Power Consumption
|
1.1w maximum
|
|
Current Loop Loads
|
Rload, max = (Vsupply-12) x 50 ohms
|
|
Analog Output (±1mA)
|
19mA/5mA self-test fault (field-selectable)
8mA dry/16mA wet (field-selectable)
16mA dry/8mA wet (field-selectable)
|
|
|
Operating Specifications—Relay and Two-Wire
|
|
Self-Test
|
Continuous for electronics and sensor, including crystal bond to sensor body
|
|
Manual Loop Test
|
All output conditions momentarily change to the opposite state (except when in a fault condition) when supplied magnet
is placed over the housing cover at the location marked “Loop Test”
|
|
Sensor Qualification Time
|
0.3 or 12 seconds, field-selectable
|
|
Repeatability
|
±0.1 in.
|
|
Enclosure
|
Single-Point: dual-compartment NEMA 4X (ANSI 250 Type 4X) enclosure housing; Materials include low copper aluminum, polyurethane paint, Buna-N O-rings
Dual-Point: single-compartment NEMA 4 (ANSI 250 Type 4) enclosure housing; Materials include low copper aluminum, polyurethane paint, Buna-N O-rings
|
|
Connection
|
Single 0.5-in NPT conduit connections; Wire range is 22 AWG to 12 AWG
|
|
Temperature Range
|
Electronics: -40°C to +70°C (-40°F to +158°F)
Sensors: -40°C to +160°C (-40°F to +320°F); -190°C to +100°C (-310°F to +212°F)
|
|
Humidity
|
10% to 95% RH, non-condensing
|
|
Operating Pressure
|
-10 to +1000 psig (-69 to +6895KPa)
|
|
Proof Pressure
|
1500 psig (10342KPa)
|
|
|
Physical Specifications
|
|
Materials
|
Gap: 316 SS, Hastelloy C, Monel, Hastelloy B, Carpenter 20, titanium; Slot: 316 SS, Hastelloy C
|
|
Weight (incl 3/4 in. NPT)
|
Single-Point model: 4 lb. (1.8kg); Dual-Point model: 6 lb. (2.7kg)
|
|
1 Both SPDT and SPST relays have gold-plated contacts and de-energize on process alarm, self-test or power loss
|
|