Sarasota SG901 (formerly SG900) Specific Gravity Analyzer Download printable brochure
The Thermo Scientific Sarasota SG901 (formerly SG900) specific gravity analyzer is a self-contained bypass sample conditioner that measures the density, pressure and temperature of dry and wet gases.
Compact model features fast response and continuous, high accuracy measurements to 0.2% of reading, making it an ideal choice for a variety of applications.
Details:
The reliable Thermo Scientific Sarasota SG901 (formerly SG900) specific gravity analyzer is a self-contained bypass sample conditioner that measures the density, pressure and temperature of dry and wet gases. This more compact model features fast response and continuous, high accuracy measurements to 0.2% of reading, making it an ideal choice for a variety of applications.
- User selectable reference conditions
- Integral sample conditioning
- Options to suit dry or wet gas applications
- Hazardous area use
- Rugged construction for harsh environments
- No on-site calibration required
The rapid response of the SG901 ensures effective burner, furnace and flare gas monitoring and control. It is recommended in applications where specific gravity (SG) or molecular weight (MW) can be used to infer density elsewhere in the plant and where the gas is dirty or wet and requires filtering prior to the measurement. The SG901 is available in three configurations: a basic system, a dry gas system and a wet gas system. It comprises a Thermo Scientific FD900
gas density assembly, temperature element and flow control valve. Built to endure harsh environments, the SG901 requires minimal maintenance and on-site calibration is not necessary.
Compatible with: Thermo Scientific FD900, ID900 and PD900 Gas Density Meters
Compliance: CE mark
Certifications: ISO 9001:2000
Recommended for:
- Gas blending control
- Standard volume flow control
- Refinery fuel gas monitoring (CV estimate)
- Oven/furnace gas monitoring (CV estimate)
- Flare control systems (MW monitoring)
|
Specifications
|
|
Functional Specifications
|
|
Range
|
0-2 SG; for any other range, consult Thermo Fisher
|
|
Accuracy
|
±0.2% reading above 0.5 SG at reference conditions
|
|
Repeatability
|
±0.02% span
|
|
Flow Range
|
Ideally 4L/min to 20L/min (0.14 ft.3/min to 0.7 ft.3/min)
|
|
Temperature Coefficient (Corrected)
|
0.01%/°C (0.006%/°F)
|
|
Operating Temperature
|
Standard: -20°C to +55°C (-4°F to ++131°F) or as limited by gas dew point; for other temperature ranges, consult Thermo Fisher
|
|
Sample Inlet Pressure
|
Basic system: standard 4 bar A (58psi); for others to a maximum 20 bar (290psi) consult Thermo Fisher Dry or wet gas system: 200 bar (2900psi) maximum
|
|
Exhaust Pressure
|
Must be less than 4 bar A (58psia), and less than the regulated inlet pressure by 0.4 bar A (5.8psia)
|
|
Environmental Rating
|
IP65 (NEMA 4X)
|
|
Physical Specifications
|
|
Spool Materials
|
Ni-Span C or FV520B
|
|
Tubes and Fittings Materials
|
Stainless steel (316L /1.4404)
|
|
System Enclosure Materials
|
Stainless steel
|
|
Electronics Enclosure Materials
|
Copper free aluminum grey epoxy finish; Plate glass window for headmounted electronics local display option
|
|
Temperature Measurement
|
High accuracy 1/3 DIN 4 wire PT100 (RTD)
|
|
Dimensions
|
10.06D x 25.99W x 33.87 in. H (255 x 660 x 860cm)
|
|
Net Weight
|
Up to 132 lb. (60kg) depending on system
|
|
Shipping Weight
|
Up to 207 lb. (94kg) ( depending on system)
|
|
Shipping Dimensions
|
37 x 37 x 27 in. (approx 940 x 940 x 270mm )
|
|
Installation Configuration
|
0.25 in. (6.35mm) tubing compression fitting
|
|
Electrical Connections
|
Instruments, IS screw terminals in FD900 terminal box (F & H versions); Heater, screw terminals in ExD enclosure
|
|
Power Supply
|
F option: frequency output: Density transmitter: 16-28VDC 10mA average (peak 18mA); Pressure transmitter: 9-30VDC 20mA
H option: headmounted electronics 3: 3 x 13-28VDC 25mA
|
|
Outputs
|
F option: frequency output: Frequency related to density on 2 wire current modulated loop 6mA to 18mA; 4 wire PT100; 4-20mA pressure
H option: headmounted electronics: Analog 4-20mA related to SG, density, or density derived variable; HART protocol
|
|