Thermox brand of analyzers
|
|
Industry standard Oxygen Insitu-probe, good to 1250 F (677 C) flue gas temperature, with unique modular design facilitating maximum on-flange accessibility to critical components including filter.
-
WDG-1200/1210 Oxygen Probe - Rugged, user friendly, low cost, reliable flue gas analyzers for net oxygen measurement are available in two models - the 1200 features a controller/display mounted on the end fo the probe for easy installation and the 1210 has a wall mounted controller/display. The controller features precision temperature control for optimum stability, built-in diagnostics,
and over-temperature protection. Modbus and 4-20 mA outputs are standard; automatic calibration is available.
-
LCC - Low cost, self-contained insitu probe with digital display on the probe head. Ideal for light oil or gas-fired, horsepower-rated package boilers and for OEM applications.
-
Insitu Replacment Probes -Thermox technology, reliability and service are now available for plug-and-play with your existing Yokogawa, Westinghouse or Rosemount electronics. Direct replacement probes are available for Yokogawa ZO21, Westinghouse 218 and Rosemount WC3000 and Enotec assemblies.
Download brochure: WDG1200/1210 Insitu O2 Analyzer
|
|
Available Models:
-
WDG-HPII - OXYGEN Unique Chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPII is ideal for challenging oxygen measurement applications in cement and lime kilns, foundry operations, waste to energy boilers, and fluidized bed combustion systems. High
performance probe and filter materials allow sampling of flue gas streams with temperatures to 2800°F (1537°C).
-
WDG-HPIIC - COMBUSTIBLES/OXYGEN Unique Chimney-effect/convective sampling technology that incorporates the advantages of insitu probe high particulate sampling with high temperature and corrosion resistance of extractive analyzers. The HPIIC is ideal for Combustibles and oxygen measurement on applications in cement and lime kilns, foundry and metals production furnaces, coal, wood waste and
heavy oil-fired boilers, black liquor recovery boilers. High performance probe and filter materials allow sampling of flue gas streams with temperatures to 2800 deg. F (1537 deg. C).
Download brochures: Insitu 2000 WDG HPII
|
|
Available Models:
-
WDG-IV - OXYGEN/Continuous-Loop sampling and Chimney-effect Convection stack recreates combustion process archetecture within the sensor for highly representative and fast response to changes in flue gas oxygen. Ideal for gas/oil-fired refinery process heaters, reformers, and power or steam boilers with rapidly changing loads. High performance probe and insitu filter materials adapt sensor to coal and
other solid fuel-fired applications. High temperature metal and ceramic probe materials allow sampling to 3200°F (1760°C).
-
WDG-IVC - COMBUSTIBLES/OXYGEN w/o METHANE/Continuous-Loop sampling and Chimney-effect Convection stack recreates combustion process archetecture within the sensor for highly representative and fast response to changes in flue gas combustibles and oxygen. Methane detection option for gas-fired purge-down/lite-off safety. Ideal for gas/oil-fired refinery process heaters, reformers, and power or steam
boilers with rapidly changing loads. High performance probe and insitu filter materials adapt sensor to coal and other solid fuel-fired applications. No-compromise sensor construction allows placement of sensor in high ambient temperature zones where measurment dictates.
-
WDG-IV UOP/RP - Close-coupled extractive-continuous loop with return to process sample exhaust low level oxygen analyzer for use in UOP Continuous Catalyst Regeneration process. Suitable for process pressures up to 45 psig.
Download brochure: WDG-IV
|
|
|
Furnace Atmosphere Control Analyzers
|
|
Analyzers for Combustion Premix Burner Stations
These analyzers are used in glass container and fiber glass manufacturing plants for post combustion analysis of glass furnace flue gas and pre combustion analysis of forehearth and fiberizer burner premix stations.
Available Models
-
CMFA-P 2000 - Transportable analyzer typically used in glass container manufacturing plants. The CMFAP (Combustion Mix Flue gas Analalyzer) is capable of post combustion spot sampling at the checker ports on glass furnaces and pre-combustion analysis of air to fuel ratio settings on forehearth premix
zones.
-
PreMix 2000 - Fixed system analyzer used for pre-combustion analysis of forehearth and fiberizer burner stations on fiberglass manufacturing lines.
Download brochure: CMFA-P 2000 Portable Premix Gas Flue Gas Analzyer
|
|
Analyzers for inert gas atmospheres
Analyzers for PPM level Oxygen measurement of inert blanketing gas atmospheres for coating, curing, and surface treatment processes.
Available Models:
-
TM2000 Oxygen Analyzer - The TM2000 oxygen analyzer protects industrial processes by quickly responding to changes using an industry-proven zirconium oxide sensor. It operates within a wide operating range of 0.1 ppm to 100% oxygen, and can accurately respond from atmosphere to low ppm oxygen levels in just seconds. In addition, the TM2000 can
detect excess combustibles process upsets in the presence of very low ppm oxygen readings. This unique benefit is particularly important in cryogenic gas generating processes, where the TM2000 can distinguish between an oxygen upset condition and an excess combustibles upset condition. The TM2000 is supported by the state-of-the-art Series 2000 controller, with input and output electronic transient protection and a standard
weatherproof housing. The controller is housed separately from the sensor.
-
CG1100 Oxygen Analyzer - The CG1100 is a smart sensor capable of detecting oxygen in your sample from 0.1 ppm to 100%. This analyzer is designed specifically for use in applications where fast response over a wide range of oxygen is required. The sample can be pulled through the analyzer using an aspirator (optional) thereby
eliminating the need for a sample pump. The CG1100 uses a zirconium oxide sensor that provides quick response, is non-depleting, and will not fail to zero reading, thereby protecting your process.
Download brochure: GC1000
|
|
Analyzers for Flame Treating, Reducing/Oxidizing Atmospheres, & Stoichiometric A/F Ratio
Extended Range ZrO2 software enabled combustion analyzers for air/fuel ratio adjustment of syngas-fired furnaces and sub-stoichiometric furnace atmospheres.
Available Models:
-
S A/F IQ - Stoichiometric Air-to Fuel Ratio analyzer for Steel Mill blast furnace and coke oven gas blending for BTU stabalization.
-
WDG-IV WITH EXCESS FUEL OPTION - A Continuous-loop sampling and chimney-effect convection stack sensor combine with powerfull extended range ZrO2 technology for accurate measurement of oxidizing/reducing furnace atmospheres.
|
|
|
Oxygen and CO analyzers for CEM and flue gas conditioning systems
|
|
Analyzers for Continuous Emissions (Pollution) Monitoring Systems and Wet/Dry ESP outlet flue gas scrubbing.
Component Wet/O2 Analyzers for CEM Systems Integration.
ZrO2 self-contained Oxygen analyzers in compact enclosure for CEM systems wet/O2 analysis.
Available Models:
-
CEM/O2 - Stand-alone ZrO2 Oxygen analyzer capable of making wet or dry oxygen measurement for replacement of exisiting ZrO2 based CEM systems analyzer or addition to existing CEM system.
Download brochure: CEM O2 CEM Humox
|
|
www.ametek.com
For more information contact us at:
(978) 532-1330 or eta@etaassociates.com
|
|
|