x
  

         ETA ASSOCIATES
         

                             

Adivision of Safety Incorporated  

go to site
 
119 Foster Street
Bldg., #6
Peabody, MA 01960
Tel: (978) 532-1330
Fax: (978) 532-7325
eta@etaassociates.com
 

 

 

Home          Technical Resources          Calibration & Repair          Battery Repair & Rebuild           Request Information           Contact Us
    


     
   

Manufacturers Represented:

Ametek Process Instruments

Badger/Data Industrial

Baseline/Mocon

Berkeley Nucleonics

Bud Industries

Cease Fire

Delta F Corp

Draeger Gas Detection Systems

Eldridge Products

Gasmet

H2Scan

Horiba Instruments

ION Science

Kahn Instruments

Kanomax

KD Engineering

McMillan Company

Percival Scientific

Perma Pure LLC

Precisive Instruments

Testo

Thermal Gas Systems

Quick Links:

About Us

Newsletter

News and Events

Linecard

Site Map



Sign up for our Email list:






We will not distribute your information.










 

ETA News
ETA Associates merges with Safety Inc.

more information

A Tribute to
ED GREEN
    


 

 Badger Meter/Data Industrial - Badger Meter’s impeller products and water flow sensors are used to measure liquids in a variety of industrial and commercial markets. These insertion and inline impeller meters serve a wide range of markets including irrigation, HVAC, energy management, water treatment, fire fighting apparatus and general industrial. Additionally, Badger manufactures and markets Btu monitors and transmitters that are compatible with virtually all energy management systems. The Impeller Products division also offers wireless RF flow sensors to the turf and agricultural irrigation markets utilizing its years of expertise in the Automatic Meter Reading market. Data acquisition and data management systems are also offered either by direct wire connections or via a wireless mesh network technology. 

Sensors
Badger 380 Series Btu System 380 Series Btu System
The Badger® Series 380 Btu Systems provide a low cost system for metering cold or hot systems. The 380CS/HS can accurately measure flow and temperature differential to compute energy. Utilizing either BACnet or Modbus RS-485 communications protocols or a scaled pulse output, the Btu Meter can interface with many existing control systems. Download brochure.
Badger 250-228 Flow Sensors 1 1/2" - 4" 250-228 Flow Sensors - 1/2" - 4"
Part of the 200 series which utilize a variety of plastic and metal service tees, they offer a simple method of installing a flowmeter in smaller line sizes. Download brochure 228 Flow Sensor. Download brochure 250 Flow Sensor.
Badger Series 200 Irrigation Flow Sensors 1/2" or larger Series 200 Irrigation Flow Sensors - 1/2" or larger
The Data Industrial IR Series flow sensors are "environmentally hardened" versions of the standard DI flow indicators. These IR versions are specifically designed for installation in underground vaults that might be subjected to flooding.

Badger PVC Sensor Series 1/2" - 4"

 
PVC Sensor Series - 1/2" - 4"
Designed for use in water filtration systems, or other liquid systems employing PVC piping. These sensors consist of Schedule 80 PVC tees fitted with a removable sensor insert. They are available for 1 1/2", 2", 3", 4" pipe sizes.

Download brochure.
Badger SDI Sensor 1 1/2" - 36" SDI Sensor - 1 1/2" - 36"
The SDI Series is a line of full-featured stainless steel or bronze body insertion flowmeters suited for a wide variety of applications. Offering an assortment of wetted materials, several output choices, a battery power option, and a data logger option, these meters are a complete flow metering package. Download brochure Hot Tap Flow Sensor. Download brochure Insert Flow Sensor.
Badger 200 Series SEnsors 3" or larger 

200 Series Sensors - 3" or larger
Available in Brass, Stainless Steel, Hot Tap and Insertion Flow models.
Download brochure Model 225 & 226 Hot Tap Flow Sensors
Download brochure Series 200 Insertion Flow Sensors
Download brochure 220PVCS Insert Flow Sensor

Badger 4000 Series SEnsor - 1/2", 3/4", 1"  4000 Series Sensor - 1/2", 3/4", 1"
A compact lin-line style impeller flowmeter, available in either PVC or  PVDF materials with several end connections and wetted material options are available, with pulse, 4-20mA output, and raw pulse options. Download brochure.
Badger Wireless Sensors  Wireless Sensors - 1 1/2", 2", 3", 4"
Includes the flow sensor, RF transmitter and RF receiver. For locations where power and output wiring is difficult to install. Download brochure 350EV seriesDownload brochure 228PV series.   Download brochure 350 Series.
Monitors< TD>
Badger 3000 Series Compact Digital Flow Meter 3000 Series Compact Digital Flow Monitor
Displays flow rate and flow total on alphanumeric display. Calibration, selection of measurement units and output programming is menu driven using keypad.
Download brochure.
Badger 3050 Series BTU Monitor  3050 Series BTU Monitor
Provides an accurate measurement of total thermal energy along with temperature and liquid flow in closed pipe systems. It has all of the features and programming flexibility of the Model 3000 flow monitor with the added ability to accept temperature inputs from thermistors or rtds. Download brochure.
Badger 2100 Series Flow Monitor 2100 Series Flow Monitor
A full featured versatile meter, accepts inputs from any type of sensor. Large 2 line alphanumeric display with optional backlighting displays rate or total in any unit of measurement. Single and dual input models available. Download brochure.
Badger 2200 Series Batch Controller  2200 Series Batch Controller
A full featured batch controller in the same user friendly package as the Series 2100. Use the menu driven software and front keypad to calibrate the flow sensor, select units of measure and enter batch size, and the 2200 will count up or down until the batch is complete. Download brochure.
Badger 2300 Series BTU Monitor  2300 Series BTU Monitor
Provides an accurate measurement of total thermal energy along with temperature and liquid flow in closed pipe systems. The Btu meter has all of the features and programming flexibility of the Series 2100 flow monitors with the added ability to accept temperature inputs from thermistors or RTDs. Download brochure.
Transmitters
Badger 310 Series Programmable Analog Transmitter  310 Series Programmable Analog Transmitter
A loop powered, programmable transmitter capable of converting the signal from Data Industrial or other manufactures flow sensors to a linear 4-20mA analog signal. Download brochure.
320 Series Programmable Pulse Output Transmitter
A compact, programmable transmitter capable of converting the signal from Data Industrial or other manufactures flow sensors to a scaled units/pulse signal. Download brochure.
Badger 330 Series Relay Transmitter 330 Series Relay Transmitter
A compact, programmable relay control capable of converting the signal from a Data Industrial flow sensor into a flow switch.
Applications: Combined with a flow sensor the Model 330 may be used in a variety of "Flow Switch" applications: Flow / no flow indicator; High Flow / Low Flow alarm monitor; Booster pump control; Multiple pump staging; Leak control.
Download brochure.
Badger 340 Series Programmable BTU Transmitter 340 Series Programmable BTU Transmitter
For sub-metering applications. Download brochure.
Badger 340BN Series BACnet Energy Transmitter  340BN Series BACnet Energy Transmitter
For sub-metering applications that utilize the BACnet® communications protocol. Download brochure.
Badger 340MB Modbus Energy Transmitter 340MB Modbus Energy Transmitter
For sub-metering applications that utilize the Modbus communications protocol. Download brochure.
Badger 340LW Series Programmable BTU Transmitter  340LW Series Programmable Btu Transmitter
For sub-metering applications that communicate via a LONWORKS® network. Download brochure.
340N2 Series Programmable BTU transmitter
For sub-metering applications using Johnson Controls Metasys® Network Companion™ and Facilitator™ Supervisory Systems. Download brochure.
Badger 500 Series Analog Transmitters 500 Series Analog Transmitter
A 4-20mA current converter normally used as a loop-powered device for use with all Data Industrial non-magnetic flow sensors. Applications: Chemical Feed Systems; Batch Control Systems; Mixing/Blending Systems; Data Logger Systems; SCADA & Recorder Systems; Energy Management Systems; BTU Measuring Systems; Irrigation Control Systems; Heat Exchanger Systems.  Download brochure.
Badger 600 Series Pulse Output Transmitter 600 Series Pulse Output Transmitter
Model 600 (housed) and 650 (unhoused) Pulse Output Transmitter is a compact electronic device that receives input signals from any Data Industrial, non-magnetic Impeller Flow Sensor.
Badger 9-- Series Local Adjustable Relay Control 800 Series Local Adjustable Relay Control
A compact single set point relay control that is designed to work with any Data Industrial nonmagnetic flow sensors to provide a simple and flexible means of control based on flow rate. Download brochure.
Data Acquisition

Badger Model 3700 Data Acquisition Series

 
Model 3700 Data Acquisition Series
Allows easy and efficient data acquisition with no special software; meters connected with up to 8 inputs or via the standard modbus.
Download brochure.
Badger 345WT Mesh Network Receiver

Model 345WT Mesh Network Receiver
With a 3700, allows for a mesh network that provides additional connnectivity for more sensors.
Download brochure.

www.badgermeter.com
For more information contact us at:
(978) 532-1330 or eta@etaassociates.com


 
ETA ASSOCIATES • 119 Forest St., Bldg. # 6 • Peabody, MA 01960 • Tel: 800-555-1234 •  Fax: 978-532-7325 Email: eta@ETAassociates.com