Baseline – MOCON, Inc. markets a full line of gas detection equipment including the award winning piD-TECH® Plug-In Photoionization Sensor, Model 9000 and Model 8800 Total Hydrocarbon/VOC Analyzers, and Model 8900 automated online Gas Chromatographs.

Our history includes over 35 years of experience providing toxic gas monitoring systems, air quality testing equipment, and top-of-the-line gas detection equipment and analyzing systems that combine selectivity, sensitivity, and accuracy with reliability, operational simplicity, and serviceability.


Exposure to toxic Gases
Ethylene Oxide, Vinyl Chloride
Acrylonitrile, Butadiene, Styrene,
Solvents, Halogenated, Compounds...

Ambient Air Monitoring
Methane/Non-Methane
Hydrocarbons

 

On-Line Process Gases
Beverage CO2 Impurities
Total Carbon (HC's + CO/CO2)
Trace Impurities in Industrial Gases

Fugitive Emissions
Perimeter Monitoring
BTEX
Method 21

Mud Logging
Fast C1 TO C5 Analysis

Source Monitoring
Method 25A
Abatement System Efficiency

piD-TECH® Plug-In Photoionization Sensor

photoionization detector

The piD-TECH® Plug-In photoionization sensor is designed to be installed in portable and stationary gas monitors that accept City TechnologyTM4P cells. It provides complete photoionization detection capability in a package that has the same dimentional and electrical profile as these cells.

  • City TechnologyTM= 4P cell platform compatible
  • Complete Sensor Including:
  • Detector Cell
  • Photoionization Detector Lamp
  • Lamp Driver
  • Amplifier
  • Sample Filter
  • Lamp Energy=10.6eV
  • Intrinsically Safe

piD-TECH® - Performance Characteristics

Target Gases: VOC's & other gases with ionization potentials <10.6eV. An ionization potential list is available upon request
Lamp Energy: 10.6eV
T90Response Time: < 20 secconds, diffusion mode
Power Consumption: 125mW typical
Power Voltage: 3.3 to 5.0 VDC
Onboard filter: To remove liquids/particles
Temperature Range: 0°c to 40°c
Relative Humidity Range: 0 to 90% non-condensing
Humidity Response:
<2ppm @ 90% RH, 25°c
Expectived Operating Life: >1 year


Physical Characteristics

Package Type: City TechnologyTM4P
Weight: < 8g (approx.)
Position Sensitivity: None
Certifications: USA: UL 913, Class I, Division 1, Groups A,B,C,D
Canada:  CSA C22.2 No. 157
Europe: ATEX directives EN50014 and EN50020, EEx ia IIC T4 and CE
Warranty Period: 18 months from date of shipment or 12 months from date of installation, which ever comes first
Lamp Replacement: Lamps are replaced by a cell exchange program

Model 8800 PID Total Volatile Organic Vapor Analyzer

The Model 8800 PID has a photoionization detector (PID) and an incredible dynamic range from 10 ppb to 1%. It is designed to analyze hundreds of volatile organic compounds (VOCs) and various other gases. The analyzer is relatively humidity insensitive and can be configured with internal components for a single or multipoint analysis of noncondensing gas samples.

  • Automatic calibration
  • Programmable virtual analog ranges
  • Programmable relays
  • RS-485, RS-232 output

Model 8800 PID Analyzer - Product Specification

Sampling: Internal single or multipoint modules, with or without sample pump(s), for prefiltered (< or = .1 microns), non-condensing samples
Calibration: Programmable automatic, or manual (with internal selection valves)
Detector: Photoionization detector (PID)
Lamp: Energies: 10.6 eV (life span >6000 hrs), 11.7 eV (life span approximately 140 hrs).
MDQ: Minimum detectable quantity: <0.1 ppm (as isobutylene), <0.1 ppm (as benzene).
Quenching: Signal quenching due to moisture:< 30% at 95% R.H. and 23° Celsius.
Range: Analog - Virtual range with software selectable endpoints provides full-scale ranges from 1.0 ppm - 1% (as isobutylene)

Digital - Display auto-ranges from 0.01 ppm to 1% (as isobutylene)
Linearity: Linear range: 0 - 10,000 ppm (isobutylene). Accurate to ± 1 ppm or ± 15% of reading, whichever is greater.
Drift: Sample dependent. Zero:< 0.1 ppm (as isobutylene) over 24 hours. Span: 100 ppm isobutylene,< 3 % over 24 hours.
Response Time: Isobutylene:< 6 Seconds to 90% of final reading
Output: Analog - 1 (standard) to 15 programmable 0-20 mA or 4-20 mA loop power supplied, isolated outputs or  optional 0-1 V, 0-5 V, or 0-10 V isolated outputs. Selectable for concentration, temperature, flow (fuel, air, or sample).

Digital - Standard: RS-485 output (RS-232 option).
Relays: 5 (standard) to 15 programmable (latched/not, NO/NC) contact closures (1A@30V max).  Selectable for alarm thresholds or events (calibration, fault, or sample location).
Alarms: Multilevel concentration, average concentration, and fault

Audible - Horn: Sounducer, generating 85 dB @10 cm. Selectively en-/disabled for keypad input, fault, and alarms.
Physical: Dimensions: 19.00" W x 16.00" D x 8.75" H (48.26 cm W x 40.64 cm D x 22.23 H). Nominal weight: 30 lb (13.64 kg).
Configuration: Bench-top or rack-mount (19" panel)
Display: Digital vacuum fluorescent, 20 characters x 2 lines
Power: 90-120 VAC or optional 210-230 VAC,  50-60 Hz
Operating Conditions: Temperature: 32-104 °F (0-40 °C). Humidity: 0-95%, non-condensing.
Gas Specifications: Span - Isobutylene, or as required by application

Connections - 1/4" O.D. Tube fitting connectors (1/8", 4 mm, and other options)

Model 8800 PID Analyzer - Options & Accessories
Samplers: Internal multipoint module, with or without internal sample pump(s), available in 4-point or 8-point configurations
Enclosures: General purpose, X-purged or Z-purged
Expansion Boards: Analog - Provides 4 or 10 additional programmable 4-20 mA outputs, with sample read & hold

Relay - Provides up to 10 additional programmable relays
Calibration Gas: Zero and span gases for a variety of applications

Model 8900 Gas Chromatograph

The Model 8900 is microprocessor-based, which, along with a variety of detector and gas train options, gives the instrument the flexibility and precision necessary to effectively perform most applications.

  • Accurate & specific to a wide variety and range of gases
  • Continuous unattended operation
  • Automatic baseline correction for long-term stability
  • Analog, digital and logic output


Model 8900 Gas Chromatograph - Product Specification
Sampling: Single point analyzer for prefiltered (< or = .1 microns), non-condensing samples

Valves - Standard: (1) 10-Port valve (additional valve optional)
Columns: Packed or capillary
Calibration: Automatic using a dedicated standard
Detector: Single or dual detector systems (detectors listed under Options & Accessories)
Oven: Temperature - Ambient to 150 °C (± 0.1 °C)
Output: Analog - Standard: (1) 0-20 mA or 4-20 mA loop power supplied, isolated.
Selectable for: gas concentration, unintegrated detector signal or diagnostics (See Options & Accessories for additional outputs)

Digital - Standard: RS-485 output (RS-232 converter option).
Physical: Dimensions: 19.00" W x 16.00" D x 8.75" H (48.26 cm W x 40.64 cm D x 22.23 H). Nominal weight: 30 lb (13.64 kg).
Configuration: Bench-top or rack-mount (19" panel)
Display: Digital vacuum fluorescent, 20 characters x 2 lines
Power: 90-260 VAC, @ 50-60 Hz (as specified)
Operating Conditions: Temperature - 32-104 °F (0-40 °C)

Humidity - 0-95%, non-condensing
Gas Connections: 1/4" or 1/8" O.D. Tube fitting connectors

Model 8900 Gas Chromatograph - Options & Accessories

Samplers: • Built-in or external sample pump
• Additional 10-port valve (consult factory)
• Injection port (on sample loop)
Detectors: • Photoionization (PID) 10.6 eV or 11.7 eV
• Flame Ionization (FID)
• Thermal Conductivity (TCD) detector(s)
• Consult factory for other options.
Output Devices: • Up to 10 additional programmable 4-20 mA outputs.
• Voltage outputs: 0-1 V, 0-5 V or 0-10 V
• Up to 10 additional programmable relays
Software: SkyChrom™ external integration, GC setup and acquisition software for PC
Enclosures: General purpose, wallmount, X-purged or Z-purged
Gas Generators:
Zero air or hydrogen
Calibration Gas:
Span gases for variety of applications

www.baseline-mocon.com

For more information contact us at:

(978) 532-1330 or eta@etaassociates.com

 
         